Gas Analyzers

This section introduces the main features and specifications of each Gas Analyzers. Envitech provide various types of these analyzers for air monitoring of SO2, H2S, TRS, NO, NO2, NOx, NH3, CO, CO2, O3 and more. 

Following tabs are the support list Envitech provided for user's choice.

 

Model T200

 

Chemiluminescence NO/ NOX/ NO2  Analyzer

 Envitech Air quality Monitoring Gas Analyzer Model T200

Main Features

 

  • Ranges: 0-50 ppb to 0-20 ppm, user selectable
  • Independent ranges and auto ranging
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time 

 

General Aspects

 

The Model T200 NO/NO2/NOx analyzer, a trademark of Envitech LTD uses the proven chemiluminescence detection principle, coupled with state-of the-art electronics to allow accurate and dependable low level measurements for use as an ambient analyzer or dilution CEMS monitor.
A unique AutoZero feature provides superb stability by continuously correcting for zero drift, while advanced Adaptive Filtering allows the analyzer to optimize performance under changing conditions. The Model T200 includes a permeation inlet dryer for ozone generation to provide excellent reliability with no periodic replacement required. A catalytic exhaust ozone scrubber is standard for maximum safety and pump life.
All T Series instruments offer an advanced color display,capacitive touch screen, intuitive user interface, flexible I/0, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software 
    

 

Main Specifications

 

  • Measurement Units: ppb, ppm, μg/m3, mg/m3 (selectable)
  • Zero Drift: < 0.5 ppb/24 hours
  • Span Drift: < 0.5% of full scale/24 hours
  • Lag Time: 20 seconds
  • Rise and Fall Time: < 60 seconds to 95%
  • Linearity: 1% of full scale
  • Precision: 0.5% of reading above 50 ppb 
  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Analog Output Ranges: 10V, 5V, 1V, 0.1V (selectable) 
  • Dimensions (HxWxD): 7” x 17” x 23.5” (178 x 432 x 597 mm)
  • Certifications: US EPA: RFNA-1194-099, MCERTS: Sira MC 050068/05
      

Download Datasheet 

Model T201

 

Chemiluminescence NH3 Analyzer

  Envitech Air quality Monitoring Gas Analyzer T201

Main Features

 

  • Ranges: 0-50 ppb to 0-2,000 ppb, user selectable
  • Independent ranges for NH3, NO, NO2, NOx
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation
  • Comprehensive internal data logging with programmable averaging periods

 

  

       

General Aspects

 

The Model T201 combines a specially configured chemiluminescence analyzer with an external thermal converter to give stable and repeatable NH3 measurements at very low levels.  In addition, the T201 provides simultaneous values for NO, NO2, and NOx concentrations.  The T201 is ideal for trace ammonia monitoring applications in ambient air as well as in clean rooms and make-up air units.  Optional zero and span valves allow automatic, unattended calibration checks.
The Model T201 achieves its remarkable stability by means of an AutoZero valve which measures and corrects for zero noise.  Multiple self-checks are performed continuously to insure maximum up-time while an innovative sample path, plumbed with specially conditioned materials, preserves the NH3 sample and reduces interferents to a minimum.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.

 

Main Specifications

 

  • Lower detectable limit: 1 ppb
  • Measurement Units: ppb, ppm, μg/m3, mg/m3 (selectable)
  • Zero Drift: < 0.5 ppb/24 hours
  • Span Drift: < 1% of full scale/24 hours
  • Linearity: 1% of full scale
  • Precision: 0.5% of reading
  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Operating Temperature Range: 5 - 40ºC
  • Dimensions (HxWxD): Analyzer: 7” x 17” x 23.5” (178 x 432 x 597 mm); Converter: 7” x 17” x 23.5” (178 x 432 x 165 mm)

Download Datasheet 

Model T100 

 

UV Fluorescence Sulfur Dioxide (SO2) Analyzer
  Envitech Air quality Monitoring Gas Analyzer T100

Main Features

 

  • Ranges: 0-50 ppb to 0-20 ppm,user selectable
  • Dual ranges and auto ranging
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral
  • devices and firmware upgrades
  • 8 analog inputs (optional)

 

 

 

 

  

 

 

 

 

General Aspects

 

The Model T100 uses the proven UV fluorescence principle,coupled with a state of the art user interface to provide easy,accurate, and dependable measurements of low level SO2.
Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon ‘kicker’ and advanced optical design combine to prevent inaccuracies due to interferents.
All T Series instruments offer an advanced color display,capacitive touch screen, intuitive user interface, flexible I/0, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.

       

Main Specifications

 

  • Measurement Units: ppb, ppm, μg/m3, mg/m3 (selectable)
  • Zero Drift: < 0.5 ppb/24 hours
  • Span Drift: < 0.5% of full scale/24 hours
  • Precision: 0.5% of reading above 50 ppb
  • Sample Flow Rate: 650 cm3/min ±10%
  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Analog Output Ranges: 10V, 5V, 1V, 0.1V (selectable)
  • Dimensions (HxWxD): 7” x 17” x 23.5” (178 x 432 x 597 mm)
  • Certifications: US EPA: EQSA-0495-100, MCERTS: Sira MC 050067/04

Download Datasheet 

Model T102 

 

UV Fluorescence TRS Analyzer
  Envitech Air quality Monitoring Gas Analyzer T102 TRS

Main Features

 

  • Ranges: 0-50 ppb to 0-10 ppm TRS and up to 20 ppm SO2, user selectable
  • Independent ranges and auto ranging
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation
  • Auto zero system

  

  

General Aspects

 

The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.
The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%.  A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.

       

Main Specifications

 

  • Lower Detectable Limit: 0.4 ppb
  • Zero Drift: < 0.5 ppb/24 hours
  • Span Drift: < 0.5% of full scale/24 hours 
  • Linearity: 1% of full scale
  • Precision: 0.5% of reading above 50 ppb
  • Sample Flow Rate: 650 cm3/min ±10%
  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Analog Output Ranges: 10V, 5V, 1V, 0.1V (selectable)
  • Dimensions (HxWxD): Analyzer: 7” x 17” x 23.5” (178 x 432 x 597 mm); Converter: 7” x 17” x 23.5” (178 x 432 x 597 mm)

Download Datasheet 

Model T101 

 

UV Fluorescence H2S Analyzer 

 Envitech Air quality Monitoring Gas Analyzer Model T101 H2S

Main Features

 

  • Ranges: 0-50 ppb to 0-10 ppm H2S and up to 20 ppm SO2, user selectable
  • Independent ranges and auto ranging
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation
  • Auto zero system

  

General Aspects

 

The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.
The Model T101 is equipped with an internally mounted catalytic converter set at 315°C to convert H2S to SO2.  A switching mode alternately measures H2S and SO2 while showing both readings concurrently on the front display.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.
      

Main Specifications

 

  • Measurement Units: ppb, ppm, μg/m3, mg/m3 (selectable)
  • Zero Noise: < 0.2 ppb (RMS)
  • Span Noise: < 0.5% of reading (RMS) above 50 ppb
  • Lower Detectable Limit: 0.4 ppb
  • Zero Drift: < 0.5 ppb/24 hours
  • Span Drift: < 0.5% of full scale/24 hours
  • Lag Time: 20 seconds
  • Rise and Fall Time: < 120 seconds to 95%
  • Linearity: 1% of full scale
  • Precision: 0.5% of reading above 50 ppb
  • Sample Flow Rate: 650 cm3/min ±10%
  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Dimensions (HxWxD): 7” x 17” x 23.5” (178 x 432 x 597 mm)

Download Datasheet 

Model T300 

 

Gas Filter Correlation CO Analyzer
  Envitech Air quality Monitoring Gas Analyzer CO Model T300

Main Features

 

  • Ranges: 0-1 ppm to 0-1000 ppm, user selectable
  • Dual ranges and auto ranging
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation

 

 

 

 

  

 

 

 

 

General Aspects

 

The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law.
Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present.  The light path then travels through the sample cell, which has a folded path of 14 meters.  The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample.  This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.

 

Main Specifications

 

  • Lower Detectable Limit: 0.04 ppm
  • Zero Drift: < 0.1 ppm/24 hours
  • Span Drift: < 0.5% of reading/24 hours
  • Linearity: 1% of full scale
  • Precision: 0.5% of reading
  • Sample Flow Rate: 800 cm3/min ±10%
  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Dimensions (HxWxD): 7” x 17” x 23.5” (178 x 432 x 597 mm)
  • Certifications: US EPA: RFCA-1093-093; MCERTS: Sira MC 050069/04

Download Datasheet 

Model T400

 

UV Absorption O3 Analyzer
  Envitech Air quality Monitoring Gas Analyzer O3 Model T400

Main Features

 

  • Ranges: 0-100 ppb to 0-10 ppm, user selectable
  • Single pass ultraviolet absorption
  • Dual ranges and auto ranging
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time

 

 

 

  

 

 

 

 

 

General Aspects

 

The Model T400 UV Absorption analyzer uses a system based on the Beer-Lambert law for measuring low ranges of ozone in ambient air.
A 254 nm UV light signal is passed through the sample cell where it is absorbed in proportion to the amount of ozone present. Periodically, a switching valve alternates measurement between the sample stream and a sample that has been scrubbed of ozone.  The result is a true, stable ozone measurement.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.

 

Main Specifications

 

  • Measurement Units: ppb, ppm, μg/m3, mg/m3 (selectable)
  • Zero Noise: < 0.3 ppb (RMS)
  • Span Noise: < 0.5% of reading (RMS) above 100 ppb
  • Lower Detectable Limit: < 0.6 ppb
  • Zero Drift: < 1.0 ppb/24 hours
  • Span Drift: < 1% of reading/24 hours
  • Lag Time: < 10 seconds
  • Rise and Fall Time: < 20 seconds to 95%
  • Linearity: 1% of full scale
  • Precision: <0.5% of reading above 100 ppb
  • Sample Flow Rate: 800 cm3/min ±10%
  • IZS Specifications: Maximum Concentration: 1.0 ppm
  • Minimum Concentration: 0.050 ppm
  • Resolution: 0.5 ppb
  • Repeatability (7 days): 1% of reading
  • Initial accuracy: ± 5% of target
  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Dimensions (HxWxD): 7” x 17” x 23.5” (178 x 432 x 597 mm)
  • Certifications: US EPA: EQOA-0992-087; MCERTS: Sira MC 050070/04

Download Datasheet 

Model T265

 

Chemiluminescence O3 Analyzer
  Envitech Air quality Monitoring Gas Analyzer O3 Model T265

Main Features

 

  • Ranges: 0-100 ppb to 0-2,000 ppb, user selectable
  • Independent ranges and auto ranging
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation

 

 

 

  

 

 

 

 

 

General Aspects

 

The innovative T265 is an ultra-high precision ozone analyzer, based on the chemiluminescence of ozone combined with nitrogen oxide.  The T265 is safe, stable, and virtually free from interferences.  It is ideal in applications where the photometric method may have false-positive indications from fine particulates, Hg, turpines, ClO2, and VOCs.  The analyzer combines the speed of response, sensitivity and stability of our proven nitrogen oxide analyzer, with a simple user interface, to provide reliable ozone measurements under the harshest conditions.
An inexpensive external cylinder of NO provides over one year of reagent for the T265.  An innovative AutoZero system ensures zero stability.  Optional zero and span valves allow automatic, unattended calibration checks.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.

 

Main Specifications

 

  • Measurement Units: ppb, ppm, μg/m3, mg/m3 (selectable)
  • Zero Noise: < 0.3 ppb (RMS)
  • Span Noise: < 0.5% of reading (RMS) above 100 ppb
  • Lower Detectable Limit: < 0.6 ppb
  • Zero Drift: < 1.0 ppb/24 hours
  • Span Drift: The greater of (< 1% of reading or 1 ppb)/24 hours
  • Lag Time: < 10 seconds
  • Rise and Fall Time: < 20 seconds to 95%
  • Linearity: 1% of full scale
  • Precision: <0.5% of reading
  • Sample Flow Rate: 500 cm3/min ±10%
  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Dimensions (HxWxD): 7” x 17” x 23.5” (178 x 432 x 597 mm)

Download Datasheet

Model T360 

 

Gas Filter Correlation CO2 Analyzer 

 Envitech Air quality Monitoring Gas Analyzer Model T360 CO2

Main Features

 

  • Ranges: 0-2 ppm to 0-2,000 ppm, user selectable
  • Dual ranges and auto ranging
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation

  

General Aspects

 

The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law.  Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present.  The light path then travels through the sample cell, which has a folded path of 2.56 meters.
The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample.  This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.
   

   

Main Specifications

 

  • Measurement Units: ppb, ppm, μg/m3, mg/m3, % (selectable)
  • Zero Noise: < 0.1 ppm (RMS)
  • Span Noise: < 1% of reading (RMS)
  • Lower Detectable Limit: < 0.2 ppm
  • Zero Drift: < 0.25 ppm/24 hours
  • Span Drift: < 0.5% of reading/24 hours
  • Lag Time: 10 seconds
  • Rise and Fall Time: < 60 seconds to 95%
  • Linearity: 1% of full scale
  • Precision: 0.5% of reading
  • Sample Flow Rate: 800 cm3/min ±10%
  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Dimensions (HxWxD): 7” x 17” x 23.5” (178 x 432 x 597 mm)

Download Datasheet 

Model T320 

 

Gas Filter Correlation N2O Analyzer 

 Envitech Air quality Monitoring Gas Analyzer Model T320 N2O

Main Features

 

  • Ranges: 0-1 ppm to 0-1,000 ppm, user selectable
  • Dual ranges and auto ranging
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation

  

General Aspects

 

The Model T320 N2O analyzer measures Nitrous Oxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law.  Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a N2O filled chamber and a chamber with no N2O present.  The light path then travels through the sample cell, which has a folded path of 2.56 meters.
The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample.  This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.

      

Main Specifications

 

  • Measurement Units: ppb, ppm, μg/m3, mg/m3 (selectable)
  • Zero Noise: < 0.02 ppm (RMS)
  • Span Noise: < 0.5% of reading (RMS)
  • Lower Detectable Limit: < 0.04 ppm
  • Zero Drift: < 0.1 ppm/24 hours
  • Span Drift: < 0.5% of reading/24 hours
  • Lag Time: < 10 seconds
  • Rise and Fall Time: < 60 seconds to 95%
  • Linearity: 1% of full scale
  • Precision: 0.5% of reading
  • Sample Flow Rate: 800 cm3/min ±10%
  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Dimensions (HxWxD): 7” x 17” x 23.5” (178 x 432 x 597 mm)

Download Datasheet 

Model T200U NOy 

 

Ultra-Sensitive Chemiluminescence NO-NOy Analyzer 

 Envitech Air quality Monitoring Gas Analyzer Model T200U_NOy

Main Features

 

    • Ranges: 0-5 ppb to 0-2,000 ppb, user selectable
    • Independent ranges and auto ranging
    • Large, vivid, and durable color graphics display with touch screen interface
    • Ethernet, RS-232, and (optional) USB com ports
    • Front panel USB connections for peripheral devices and firmware upgrades
    • 8 analog inputs (optional)
    • Adaptive signal filtering optimizes response time
    • Temperature & pressure compensation
    • 50 ppt lower detectable limit
    • Catalytic ozone scrubber

  

General Aspects

 

The Model T200U NOy analyzer has been developed and refined specifically to address the challenges of NOy monitoring as required, for example, in the US NCore network.  It uses the proven chemiluminescence principle and is coupled with a remote NOy converter via umbilical to allow measurements with a lower detectable limit of 50 ppt.
The Model T200U analyzer combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity.  In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.  The remote NOy converter is provided with a stainless steel, NEMA 4X (IP65) enclosure and custom sample umbilical to allow a mounting height of 10 meters.  In addition, the converter features a unique purge circuit designed to remove residual calibration gas.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.

      

Main Specifications

 

  • Measurement Units: ppb, μg/m3 (selectable)
  • Zero Noise: < 25 ppt (RMS)
  • Span Noise: < 0.5% of reading (RMS) above 5 ppb
  • Lower Detectable Limit: <50 ppt
  • Zero Drift: < 0.1 ppb/24 hours
  • Span Drift: < 0.5% of reading/24 hours
  • Lag Time: 20 seconds
  • Rise and Fall Time: < 50 seconds to 95%
  • Linearity: 1% of full scale
  • Precision: 0.5% of reading above 5 ppb
  • Sample Flow Rate: 1800 cm3/min ±200 cm3/min (NO & NOy)(Includes 800 cc bypass)
  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Dimensions (HxWxD): Analyzer: 7” x 17” x 23.5” (178 x 432 x 597 mm); Flow Module: 8.75” x 17” x 23.5” (222 x 432 x 597 mm);Converter: 13.5” x 10.5” x 6.5” (343 x 267 x 165 mm)

Download Datasheet 

Model T802 

 

Paramagnetic O2 Analyzer
  Envitech Air quality Monitoring Gas Analyzer O2 Model T802

Main Features

 

  • O2 Range: 0-1% to 0-100%, user selectable
  • Dual ranges and auto ranging
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation

 

 

 

 

  

 

 

 

 

General Aspects

 

The Model T802 O2 uses the proven paramagnetic measurement principle, coupled with state of the art microprocessor technology, to provide accurate and dependable measurements of Percent-Level O2.
Paramagnetic technology is non-depleting, which means that there are no consumable parts, and ensures a consistent performance over time.  The selectivity of the paramagnetic measurement for oxygen means that there is little or no interference from other common background gases.  The T802 offers a stable and inherently linear measurement of oxygen, making it possible to calibrate the analyzer by checking only two points.  There is no requirement for a reference gas during operation.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.

 

Main Specifications

 

  • Zero Noise: < 0.02% (RMS)
  • Span Noise: < 0.05% of reading (RMS)
  • Lower Detectable Limit: < 0.04 %
  • Zero Drift: < ±0.02%/24 hours; < ±0.05%/7 days
  • Span Drift: < ±0.1%/7 days
  • Accuracy: < ±0.1%
  • Linearity: < ±0.1%
  • Temperature Coefficient: < ± 0.01% per degree C
  • Rise and Fall Time: < 60 seconds to 95%
  • Flow Rate: 120ml ±20ml/min
  • Humidity Range: 0-95% RH
  • Pressure Range: 25-31 in Hg
  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Dimensions (HxWxD): 7” x 17” x 23.5” (178 x 432 x 597 mm)

Download Datasheet 

Model T100U 

 

Ultra-Sensitive UV Fluorescence SO2 Analyzer 

 Envitech Air quality Monitoring Gas Analyzer Model T100U SO2

Main Features

 

  • Ranges: 0-5 ppb to 0-20,000 ppb, user selectable
  • Dual ranges and auto ranging
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation

  

General Aspects

 

The Model T100U Ultra-Sensitive SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network.  It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.
The analyzer uses both the light and dark phases of the pulsed UV light source to continuously detect and correct for electronic noise, giving exceptionally stable and sensitive performance.  A separate UV detector allows the instrument to continuously correct for variations in lamp intensity.  Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift, and a reference detector to correct for changes in UV lamp intensity.  A hydrocarbon “kicker” and advanced optical design combine to prevent inaccuracies due to interferents.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.

      

Main Specifications

 

  • Measurement Units: ppb, ppm, μg/m3, mg/m3 (selectable)
  • Lower Detectable Limit: 50 ppt
  • Zero Drift: < 0.2 ppb/24 hours
  • Span Drift: < 0.5% of full scale/24 hours
  • Lag Time: 30 seconds
  • Rise and Fall Time: < 140 seconds to 95%
  • Linearity: 1% of full scale
  • Precision: 0.5% of reading
  • Sample Flow Rate: 650 cm3/min ±10%
  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Dimensions (HxWxD): 7” x 17” x 23.5” (178 x 432 x 597 mm)
  • Certifications: US EPA: EQSA-0495-100

Download Datasheet 

VOC + BTEX Analyzer 

 

GC955-601 Benzene, Toulen, 1-3 butadiene and Xylene Analyzer 

 Envitech Air quality Monitoring BTEX+VOC GC955-600

Main Features

 

  • Compounds Analyzed: Benzene, Toluene, Ethylbenzene, Xylenes, 1-3 Butadiene in air
  • Measuring Technique: PID Gas chromatograph
  • Measurement Range: up to 300 ppb
  • Lowest detection level for benzene 0.1 μg/m3 (0.03 ppb)

  

General Aspects

 

The Syntech Spectras GC955 series 600 BTX analyzer is built for the measurement of benzene, toluene and xylene isomers in ambient air.
In the European regulations measurement of benzene in ambient air is now obligatory. The concentration of benzene varies from under 1 to above 100 micrograms per m3.
For authorities wanting to measure benzene our instrument is the ideal choice: our instruments are not only designed for the analyst working in the laboratory, but especially for the technician working in a field station or at a control panel. Specialized chemical knowledge is not necessary.
 

In the GC a standard industrial PC with Windows is used. This means that the whole PC structure is available to handle also the results of measurements: data are interpreted and saved on the internal hard disk. Data can also be transferred by network and modem connection. Besides this, analog and digital output options are available to communicate with other data logging systems using several data protocols.

Simple operation, good reliability and low maintenance cost are important to us. With a network of distributors in and outside of Europe you can be sure that your instrument comes complete with an individualised training and that support is available to help if you do encounter problems. The new Syntech Spectras GC955 works on only one gas, nitrogen, using a very small quantity.

      

Other Specifications

 

  • Control of instrument: direct control via keyboard or mouse, or vi remote host (RS232 /
    modem), Ethernet, data. Exchange protocols available on demand
  • Continues Monitoring
  • Included items: SERIES 600, column AT624 15m, 0.32 mm ID, 1.8 μm film,cycle time 15 min,
  • temp program 50 - 70 °C Suitable for measurement of up to 40 compounds
  • Reproducibility: typical <3% at 1 ppb (benzene, with capillary column)
  • Consumption of gas: instrument air: none!. Nitrogen: quality 5.0, 4 bar, 6 ml/min
  • Dimensions: 19" rack, 5 standard Height Units, depth 37.2 cm net
  • Power demand: 220 V AC, 100 VA (110 V AC available)
  • Included Hardware: computer Pentium III class, hard disk  40Gb, 2.5 “,display LCD
  • 10.4 “ color, various data connection options
  • Option: One PC can control 2 gas chromatographs
  • Certification: CE approval, Approval for EN14662-3

Download Datasheet 

Back to list